Tubular Motor Receiver TM5895 with Rolling Code
auto gate control tubular motor receiver
Packaging & Delivery
-
Product size
16.1 x 10.3 x 4.5 cm
-
Product weight
293 g
-
CTN. Spec
38*38*20 cm / 30unit
-
G.W/N.W
8 / 7.2 kg
-
Certification
CE
-
Frequency
433.92MHz
-
Code
Rolling code
-
Color
White
-
Working voltage
85 -265 VAC (110VAC/60HZ/220VAC /50HZ is optional according to motor)
-
Product size
150*100*40mm
-
Product weight
242g
-
Transmitters stored
30pcs
-
Suitable tubular motor
35mm, 45mm, 55mm, 59mm, 64mm, 92mm
-
Loading capacity
1HP/220VAC or 0.5HP/110VAC
-
Self-learning function
Yes
-
Working temperature
-20℃ to 60℃
-
Build-in fuse
10A
-
Running time
Nonadjustable
-
Auto close time
5~200 seconds adjustable
-
External switch one button& three button
three buttons control
-
Control
One or three buttons control
-
Operation
Deadman/Impulse adjustable
-
Connect with
Photocell,flash lamp,external switch
-
Installation position
outside type
-
With push buttons
Yes
Function
1. Learning transmitters:Press the learning button in the control board, LED is on, enters into the learning process; Press the same button twice, LED blinks for several times, then off. The learning process is successful.
2. Use the transmitter that already has been learned as old transmitter, press button 1 and button 2 at the same time. Then press button 2 to let it enters into the learning process. Press the same button on the new transmitter twice. The learning process is finished. In this way new transmitter can be learned without pressing the learning button on the control board.
3. Erasing transmitter: Press the learning button, continue pressing for 8s until LED turns off; Release learning button, LED will be on (about 1s) and then off; the erasing process is successful.
4. Button 1,2,3 in transmitter is in correspondence with open, close and stop.(The same as button on controller and the external three button control);
5. Single-button control is only effective to the learned button(The same as external single circle control).If a new button of transmitter learned into the control panel, the formal one is useless
Notes: For security, the controller is able to close the gate only after opening the gate for the first time operation.
Transmitter Operation
1. Single button (Open-stop-close-stop); Three button (Open, stop, close).
2. Deadman model: Door moves when keep pressing button and stops when release; Impulse model: Press button and door moves, press button and door stops (Gate max running time is 100s single time)
3. Infrared protection: If without auto-close function, motor stops when photocell signal disconnecting during door closing.
4. Flash lamp: Lighting or blinking (frequency is 60 times) is optional when motor is running
5. With Auto-close function, Self-learning function; Max remote distance over 50 M
* Auto-close operation (1,needs to connect photocell 2,there is no this function if in Impulse model)*

Send your message to us
No need register, just fill in contact info below, we will reply you within 24 hours!


