Sliding gate control unit SL0720 Kit
Sliding Door Control PCB Board SL0720 Kit
Packaging & Delivery
-
Product size
17.5 x 12.5 x 4 cm
-
Product weight
500 g
-
Certification
CE
-
Frequency
433.92MHz
-
Code
Rolling code
-
Working voltage
220VAC, 50Hz
-
Product size
175*130*6mm
-
Product weight
800g
-
Transmitters stored
30
-
Loading capacity
2HP 220VAC
-
Self-learning function
Yes
-
Voltage output
AC24V
-
Working temperature
-20℃ to 60℃
-
Build-in fuse
Electric circuit(0.5A); Motor(10A), pls exchange appropriate fuse according to loading capacity
-
Soft start soft stop
Yes
-
Running time
5-100S Adjustable
-
Resistance of opening and closing door
Yes
-
Electric lock
No
-
Auto reverse when meet obstacle
Yes
-
Auto close time
5/10/30S changable
-
Installation at left or right side
Yes
-
External switch one button& three button
Both
Sliding door control panel SL0720 kit, including the housing and 2 transmitters
I. Safety Instructions
1.1 To ensure safety, please read the manual carefully before your first operation; before connecting, be sure to turn off the power. 1.2
Before the first operation, please clear the device. (Reference: Clear all the learned/memorized transmitters)
1.3 To avoid accidental operation, do not learn the lighting when the motor is turned on. 1.3
The received signal may be interfered with by other communication devices. (For example, wireless control systems with the same frequency range)
1.4 This product is only applicable to manual lighting and wireless control devices/systems. These devices/systems must not endanger or compromise the safety of property or eliminate their safety risks when they malfunction. 1.5
It should be used in a dry indoor safe place or in an electrical area.
II. Technical Index
2.1 Working Voltage: 220VAC 50Hz
2.2 Temperature Range: -20℃ to 60℃
2.3 Load Capacity: 2HP 220VAC
2.4 Built-in Fuses: Circuit (0.5A); Motor (10A). Please replace the fuse with the appropriate one according to the load capacity
2.5 Soft Start Time: 1S. Soft Stop Time = 127 seconds - Quick Run Time
2.6 Quick Run Time: Adjustable range from 3 seconds to 120 seconds - Set using TP3
2.7 Frequency: 433.92MHz
2.8 Transmitter Storage: 30
2.9 Output Voltage: AC24V
2.10 Output with Flashlight: AC220V
2.11 External Switch (On, Off, Closed Loop)
2.12 External Limit Position (DIP1 selects Normally Open or Normally Closed)
2.13 External Infrared (Normally Closed Contact)
2.14 Adjustable Door and Door Closing Braking
2.15 Adjustable Automatic Shutdown Time: (Use DIP7, DIP8 to select 5 seconds, 10 seconds, 30 seconds)
2.16 Select the remote control system with or without lock using DIP4
2.17 DIP3 selects installation via the left or right side
2.18 Single-key/Tri-key Control can be selected using DIP2 switch 。 2.19 Dimensions: 140*103*38
III. Notes
After adjusting the resistance, a manual resistance test needs to be conducted to ensure that the resistance value is appropriate. 2
The on and off resistors should be checked regularly.
Send your message to us
No need register, just fill in contact info below, we will reply you within 24 hours!